Bosch Rexroth Directional Poppet Valves M-2SEW6 M-3SEW6 M-4SEW6

in stock

Directional poppet valves, directly operated with solenoid actuation
Size: 6
Component series: 3X
Maximum operating pressure: 420 bar / 630 bar
Maximum flow: 25 l/min

More details

  • Download Data Sheet DIRECTIONAL SEAT VALVES, DIRECT OPERATED, WITH SOLENOID ACTUATION TYPE SEW

Bosch Rexroth Directional Poppet Valves, Directly Operated with Solenoid Actuation Type M-.SEW 6

  • Size: 6
  • Component series: 3X
  • Maximum operating pressure: 420 bar / 630 bar
  • Maximum flow: 25 l/min
Features:
  • 2/2-, 3/2- or 4/2-way version
  • Porting pattern according to DIN 24340 form A
  • Porting pattern according to ISO 4401-03-02-0-05 and NFPA T3.5.1R2-2002D03
  • Air-gap DC solenoids with detachable coil
  • Solenoid coil is rotatable by 90°
  • The coil can be changed without having to open the pressure-tight chamber
  • Electrical connection as individual connection
  • Optional auxiliary operating device
  • Inductive position switch and proximity sensors (contactless)

General Function:

The SEW type directional valve is a directional seat valve with solenoid actuation. It controls the start, stop and direction of flow.


Domestic and export sales enquiries are welcome from end users, original equipment machinery manufacturers and trade suppliers from all industrial sectors.
If you can't find what you are looking for, need product pricing, delivery, technical support or associated services CONTACT GOKOSO or call our sales office +86 17623383975

PART NUMBER MATERIAL NUMBER IN STOCK PRICE SHIP ADD TO MY PARTS LIST

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

M

SEW

6

3X

/

M

K4

/

*


01

Mineral oil

M

02

2 main ports

2

3 main ports

3

4 main ports

4

03

Seat valve, direct operated

SEW

04

Size 6

6

05

Symbols

Main ports

● = available

2

3

4

P

N

U

C

D

Y

06

Component series 30 … 39 (30 … 39: unchanged installation and connection dimensions)

3X

07

Operating pressure 420 bar

420 bar

Operating pressure 630 bar

630 bar

08

High-power solenoid (air-gap) with detachable coil

M

09

Nominal voltage 96 V at DC solenoid with operation with AC voltage mains (AC voltage mains 110 V/120 V - 50/60 Hz with an admissible voltage tolerance of +/- 10 %)

G96

Nominal voltage 110 V at DC solenoid with operation with AC voltage mains (AC voltage mains 110 V/120 V – 50/60 Hz with an admissible voltage tolerance of +/-10 %)

G110

Nominal voltage 205 V at DC solenoid with operation with AC voltage mains (AC voltage mains 230 V - 50/60 Hz with an admissible voltage tolerance of +/- 10 %)

G205

Connection to the AC voltage mains via control with rectifier. Further ordering codes for other voltages are provided in the Technical data

10

With concealed manual override (standard)

N9

Without manual override

no code

Electrical connection

11

Individual connection

Without mating connector; connector DIN EN 175301-803

K41)

Spool position monitoring

12

Without position switch

no code

Inductive position switch type QM

Monitored spool position "a"

QMAG24 2)

Monitored spool position "b"

QMBG25 2)

13

Without check valve insert, without throttle insert

no code

With check valve insert

P

Throttle Ø 1.2 mm

B12

Throttle Ø 1.5 mm

B15

Throttle Ø 1.8 mm

B18

Throttle Ø 2.0 mm

B20

Throttle Ø 2.2 mm

B22

Other orifices on request

Seal material

14

NBR seals

no code

FKM seals

V

Observe compatibility of seals with hydraulic fluid used. (Other seals upon request)

15

Without locating hole

no code

With locating hole and locking pin ISO 8752-3x8-St

/62

16

Further details in the plain text

*

1) Mating connectors, separate order.

2) Version “420” only